888.375.8826
[email protected]

Cart:

0 item(s) - $0.00
You have no items in your shopping cart.

0

ECOTOWER FP2 3KW RECTIFIER BASE, -4

Details

ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24"" WIDE, 24"" DEEP, 7' HIGH (84"" HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) THREE PHASE 208VAC (3W+PE) INPUT, 3 RECTIFIERS PER AC INPUT FEED, FRONT ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5"" CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4""-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2400A WITH SHUNT, NO LVD PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD QTY 8 - 3/8"" ON 1"" CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25"" PER CONNECTION LOAD FUSE DISTRIBUTION, 1200A, INCLUDING: - QTY 18 TPL FUSE POSITIONS OR 12 GJ BREAKER POSITIONS WITH 36 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8"" HOLE ON 1"" CENTER, MAX CABLE TONGUE WIDTH OF 1.5"" PER CONNECTION. QTY 10 MTPLHS INSTALLED INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8""-16 NUTS ON 1"" CENTER - RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS. EPS-S02-A03-B03-D05-D05-D05-G

Additional Information

Short Description ECOTOWER FP2 3KW RECTIFIER BASE, -48V/2400A OUTPUT INCLUDES: CABINET, QTY 10 FP2 3KW RECTIFIER SHELVES AND SMARTPACK2 CONTROLLER KIT. - CABINET: 24 WIDE, 24 DEEP, 7' HIGH (84 HIGH), SEISMIC CABINET - EACH RECTIFIER SHELF HAS 4 RECTIFIER POSITIONS, TOTAL 40 RECTIFIER POSITIONS - SMARTPACK2 CONTROLLER KIT INCLUDES 1 BASIC MODULE, 1 MASTER MODULE WITH DISPLAY AND 1 I/O MONITOR2 (PROVIDES 6 CONFIGURABLE INPUTS AND 6 RELAY OUTPUTS) THREE PHASE 208VAC (3W+PE) INPUT, 3 RECTIFIERS PER AC INPUT FEED, FRONT ACCESS INCLUDES: AC CONNECTION TERMINALS, CABLE KITS AND AC INPUT JUNCTION BOX. - AC INPUT # (AC INPUT TERMINAL QTY) IS BASED ON THE QTY OF RECTIFIERS, EACH AC INPUT CONSISTS OF THREE TERMINALS, EACH TERMINAL ACCEPTS MAX. 4 AWG WIRE. - CABLE KITS INCLUDE CABLES CONNECTED FROM AC TERMINALS TO RECTIFIER SHELVES, CABLE TIES ETC. ALL THE WIRING IS DONE IN FACTORY - AC JUNCTION BOX INCLUDES 7 KNOCKOUTS FOR 1.5 CONDUIT ON THE TOP, 20 GROUNDING STUDS (1/4-20) AND MOUNTING BRACKETS BATTERY BULK OUTPUT PANEL, 2400A WITH SHUNT, NO LVD PANEL IS EQUIPPED WITH: 50mV/3000A SHUNT, NO LVD QTY 8 - 3/8 ON 1 CENTER BATTERY BULK HOT CONNECTIONS, MAX CABLE TONGUE WIDTH OF 2.25 PER CONNECTION LOAD FUSE DISTRIBUTION, 1200A, INCLUDING: - QTY 18 TPL FUSE POSITIONS OR 12 GJ BREAKER POSITIONS WITH 36 LOAD HOT LANDINGS, EACH LANDING REQUIRES TWO-HOLE LUG WITH 3/8 HOLE ON 1 CENTER, MAX CABLE TONGUE WIDTH OF 1.5 PER CONNECTION. QTY 10 MTPLHS INSTALLED INTERNAL RETURN BUS BAR INCLUDES: - BATTERY/SYSTEM RETURN BUS INCLUDES 8 LANDINGS, EACH LANDING CONSISTS OF TWO 3/8-16 NUTS ON 1 CENTER - RETURN BUS RIBS, THE SELECTION AND QTY OF RETURN BUS RIBS ARE BASED ON THE SELECTION AND QTY OF BATTERY AND LOAD DISTRIBUTIONS. EPS-S02-A03-B03-D05-D05-D05-G
SKU 305166
Product PDF N/A
HECI No
Manufacturer Eltek
Product Type N/A
Special Price No

Add Items to Cart

© Core Telecom Systems. All Rights Reserved.